AUTOSAFE MODE
SECTION 7. ADDITIONAL FUNCTIONS
The Vector Autosafe Mode automatically dials the number entered into QDial
location #01. This mode works slightly differently in the portable and rack
versions and can either be used as an STL backup function or simply as an
auto-redial in case of disconnection. Heres how it works:
Autosafe Mode is enabled from the STATUS display by pressing the number 0
on the keypad. The Vector will respond, asking whether you want to enter
the Autosafe Mode now. If you choose YES, Autosafe Mode is enabled, and
the STATUS heading on the STATUS display is replaced by AUTOSAFE. Once in
Autosafe Mode, a portable Vector will then show PREPARING TO DIAL AUTOSAFE
MODE on the display for three seconds. During this time, the user may press
the softkey labeled ABORT on the display and will be given the option to
disable AutoSafe Mode. If the call is dropped from either end, the process
will repeat, and the call will be placed again. Autosafe Mode is programmed
into nonvolatile memory and will be retained after the unit is powered
down. If a Vector has been left in Autosafe Mode, it will automatically start
the Autosafe dialing sequence as soon as power is turned on.
On the Rackmount Vector, the process is similar except that the Vector waits
until the AUX input connector is closed to initiate dialing. When the AUX
contact closure is closed, the screen will show PREPARING TO DIAL AUTOSAFE MODE
and the sequence will proceed as described above for the portable Vector.
Autosafe Mode will continue until the contact closure is opened, or until
Autosafe Mode is exited during the PREPARING TO DIAL sequence. Autosafe
Mode can also be disabled on the Rackmount Vector, if the AUX connector is
open and the user presses the 0 key from the status display. A menu will
appear asking if you want to exit Autosafe Mode. If the user selects YES, he
will return to the status display with Autosafe disabled.
In rare occasions, it is possible for the modem registers to become
scrambled, interfering with normal operation. If your Vector malfunctions,
you can try rebooting the modem. To do this, turn the power off on the
Vector and then turn it back on. When you see the INITIALIZING display, press
the HELP key to access the BOOT-UP menu. From this menu select MODEM BOOT
and then RESETTING MODEM will appear in the display. This procedure will
reset all the modem registers to the factory default state.